Effect of automation on prothrombin time test in NEQAS surveys.

L Poller, J M Thomson, D A Taberner

UK Reference Laboratory for Anticoagulant Reagents and Control, Withington Hospital, Manchester.

The performance of coagulometers in the National Quality Assessment Scheme (NEQAS) surveys of the prothrombin time conducted between 1986 and 1987 was reviewed. There were sufficient data for analysis for eight types of coagulometer used with a single type of thromboplastin reagent and one instrument with an alternative reagent. The overall reliability efficacy of each instrument was evaluated by determining the orthogonal regression slope parameters for prothrombin time (PT) and international normalised ratios (INR) using the manual technique as the reference method. Seven of the eight types of coagulometer tended to overestimate the INR. A pattern frequently observed with coagulometers, and difficult to regulate, was a trend to underestimate INR below 3.0 and overestimate higher INR. Overestimation of INR values over 3.0 was particularly pronounced with three types of instrument (Fibrintimer, Lancer, KC4/10). The KC4/10 was used by a sufficient number of participants to permit analysis of the performance of individual instruments. Within instrument differences were similar to those produced by different types of coagulometers. Thromboplastin reagents affected the INR values obtained with coagulometers. The study indicates that each local reagent-instrument combination must be calibrated by the participant to obtain reliable INR values. The use of a general correction factor for a local PT system seems to be invalid owing to the considerable variation in performance of individual coagulometers. The two best guides to the choice of coagulometer may be the deviation from the manual result and precision estimated by the coefficient of variation of the INR.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

Relevant Article

Manual and automated prothrombin time tests.
D J Easton
J. Clin. Pathol. 1989 42: 1117-1118. [PDF]

This article has been cited by other articles:

  • Lazo-Langner, A., Villa-Marquez, R., Hernandez-Hernandez, D., Rojas-Maya, S., Piedras, J. (2009). Intrahospital Correlation of the International Normalized Ratio. CLIN APPL THROMB HEMOST 15: 220-224 [Abstract]  
  • Ansell, J., Hirsh, J., Hylek, E., Jacobson, A., Crowther, M., Palareti, G. (2008). Pharmacology and Management of the Vitamin K Antagonists: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines (8th Edition). Chest 133: 160S-198S [Abstract] [Full Text]  
  • Ansell, J., Hirsh, J., Poller, L., Bussey, H., Jacobson, A., Hylek, E. (2004). The Pharmacology and Management of the Vitamin K Antagonists: The Seventh ACCP Conference on Antithrombotic and Thrombolytic Therapy. Chest 126: 204S-233S [Abstract] [Full Text]  
  • Hirsh, J., Fuster, V., Ansell, J., Halperin, J. L. (2003). American Heart Association/American College of Cardiology Foundation guide to warfarin therapy. J Am Coll Cardiol 41: 1633-1652 [Full Text]  
  • Hirsh, J., Fuster, V., Ansell, J., Halperin, J. L. (2003). American Heart Association/American College of Cardiology Foundation Guide to Warfarin Therapy. Circulation 107: 1692-1711 [Full Text]  
  • Duxbury, B. McD., Poller, L. (2001). State-of-the-Art Review: The Oral Anticoagulant Saga: Past, Present, and Future. CLIN APPL THROMB HEMOST 7: 269-275 [Abstract]  
  • Hirsh, J., Dalen, J. E., Anderson, D. R., Poller, L., Bussey, H., Ansell, J., Deykin, D. (2001). Oral Anticoagulants: Mechanism of Action, Clinical Effectiveness, and Optimal Therapeutic Range. Chest 119 : 8S-21S [Full Text]  
  • Schmitz, L. L., Olson, S. L., Shapiro, R. S., McCormick, S. R., Kubic, V. L. (1995). Failure to Generate Comparable International Normalized Ratio Values Using Five Different Thromboplastin Reagents in Parallel Studies of Patients Receiving Warfarin. CLIN APPL THROMB HEMOST 1: 142-150 [Abstract]  
  • Hirsh, J., Poller, L. (1994). The International Normalized Ratio: A Guide to Understanding and Correcting Its Problems. Arch Intern Med 154: 282-288 [Abstract]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Pathology jobs

Pathology jobs