Register for email alerts and news feeds:
This journal | BMJ Group
rss
Journal of Clinical Pathology 1989;42:307-312; doi:10.1136/jcp.42.3.307
Copyright © 1989 by the BMJ Publishing Group Ltd & Association of Clinical Pathologists.

New enzyme immunoassay for detecting total, type I, and type II intrinsic factor antibodies.

H M Waters, C Smith, J E Howarth, D W Dawson, I W Delamore

University Department of Haematology, Manchester Royal Infirmary.

A method for the detection of total, type I, and type II intrinsic factor antibodies was devised. The technique comprises a two-site solid phase enzyme linked immunosorbent assay (ELISA), with human intrinsic factor conjugated with horseradish peroxidase as label and attached to polystyrene tubes as solid phase. One conjugation provides sufficient material to assay more than 10,000 patient samples. The label proved stable during the course of this evaluation and was still in use more than 12 months after preparation. When applied to 45 serum samples from cases of pernicious anaemia, intrinsic factor antibodies were shown in 30 (67%). Simplicity, high capacity, low cost and label stability, combined with relatively high clinical sensitivity make the method suitable for cost effective screening of large numbers of samples. Simple modifications to the basic assay reagents permitted type I and type II intrinsic factor antibodies to be differentiated.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Khan, S, Del-Duca, C, Fenton, E, Holding, S, Hirst, J, Dore, P C, Sewell, W A C (2009). Limited value of testing for intrinsic factor antibodies with negative gastric parietal cell antibodies in pernicious anaemia. J. Clin. Pathol. 62: 439-441 [Abstract] [Full Text]  
  • Gomez, E. A., Ehresmann, D. D., Ledebuhr, L. K., Eastvold, M. L., Singh, R. J., Klee, G. G., Grebe, S. K.G. (2005). Development and Validation of an Automated Chemiluminometric Immunoassay for Human Intrinsic Factor Antibodies in Serum. Clin. Chem. 51: 232-235 [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Pathology jobs

Pathology jobs