Register for email alerts and news feeds:
This journal | BMJ Group
rss
Journal of Clinical Pathology 2004;57:1027-1032; doi:10.1136/jcp.2003.011551
Copyright © 2004 by the BMJ Publishing Group Ltd & Association of Clinical Pathologists.
Journal of Clinical Pathology 2004;57:1027-1032
© 2004 BMJ Publishing Group Ltd & Association of Clinical Pathologists

ORIGINAL ARTICLE

Troponin I, laboratory issues, and clinical outcomes in a district general hospital: crossover study with "traditional" markers of myocardial infarction in a total of 1990 patients

F Jishi1, P R Hudson2, C P Williams2, R P Jones2, G K Davies2, Z R Yousef1, R J Trent1, R P W Cowell1

1 Department of Cardiology, Wrexham Maelor Hospital, North East Wales NHS Trust, Croesnewydd Road, Wrexham LL13 7TD, UK
2 Department of Medical Biochemistry, Wrexham Maelor Hospital

Correspondence to:
Correspondence to:
Dr C Williams
Department of Medical Biochemistry, Wrexham Maelor Hospital, Croesnewydd Road, Wrexham LL13 7TD, UK; clive.williams{at}new-tr.wales.nhs.uk

Aims: Review of the clinical outcomes and practical issues of replacing traditional cardiac enzymes with troponin I (cTnI) in a district general hospital.

Methods: Crossover study of three sequential three month stages during which serial cardiac enzymes were replaced with a single cTnI measurement available at three set times within 24 hours for the duration of the second three month stage. The study was carried out in a 630 bed district general hospital with 1990 admissions of suspected cardiac ischaemia over the study period as a whole. Account was taken of seasonal factors.

Results: The introduction of troponin was associated with 8.5% more patients with non-ischaemic heart disease (IHD) being discharged on the day after admission, saving approximately 107 bed days each year. Approximately 50% more patients were diagnosed with myocardial infarction during the cTnI stage. There was no increase in readmission within one month or early death with cTnI. Approximately 3% false positive and 1.5% false negative cTnI results were recorded. All false positive cTnI results were coding errors or attributable to known assay interference effects. All false negatives were potentially explained by sample timing factors. The lack of standardisation in troponin assay services impacts clinically.

Conclusion: Younger patients without IHD were discharged earlier during the cTnI stage in apparent safety. Blood sample timing needs to be verified when cTnI is used as an adjunct to early discharge. There were no unexplained false positives or negatives. Standardisation related issues arose.

Abbreviations: ACS, acute coronary syndrome; AST, aspartate aminotransferase; CI, confidence interval; CK, creatine kinase; cTnI, troponin I; ECG, electrocardiogram; ICD, international classification of disease; IHD, ischaemic heart disease; MI, myocardial infarction

Keywords: troponin I; crossover study; district general hospital; false positives and negatives; early discharge


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Sharma, S, Jackson, P G, Makan, J (2004). Cardiac troponins. J. Clin. Pathol. 57: 1025-1026 [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Pathology jobs

Pathology jobs