Article Text

Download PDFPDF
Intrinsic factor antibody tests.
  1. P J Shackleton,
  2. D I Fish,
  3. D W Dawson
  1. Department of Haematology, North Manchester General Hospital.

    Abstract

    The sensitivity of methods to detect antibodies to intrinsic factor was assessed. Five sera of known antibody content were tested in 31 laboratories and 30 sera from patients with pernicious anaemia were tested in one laboratory. Five non-commercial methods and two kits for type I antibodies and one non-commercial method for types I and II antibodies are in current use. Differences in sensitivity of the non-commercial methods for type I antibodies related more to the antigen: antibody ratio in the test system than to the method itself. A radioimmune assay for types I and II antibodies showed the best sensitivity but that of an enzyme linked immunosorbent assay (ELISA) method was poor.

    Statistics from Altmetric.com

    Request Permissions

    If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.