Article Text

Download PDFPDF
Improving the detection rate of vancomycin-resistant enterococci colonisation using groin swabs

Abstract

Vancomycin-resistant enterococci (VRE) are nosocomial pathogens associated with significant morbidity in immunosuppressed patients. Stool culture is considered the gold standard for VRE screening. However, in a clinical environment, there are difficulties associated with the practicalities of obtaining stool samples. Groin swabs, routinely collected as part of the mandatory admissions policy for meticillin-resistant Staphylococcus aureus screening were used to detect VRE. In direct comparison, stool culture had better sensitivity to groin swabs. However, groin swabs with broth enrichment allowed earlier detection of VRE carriage in 14 patients from whom stool samples could not be obtained in a timely manner.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.