Clinical usefulness of serum 1,5-anhydroglucitol in monitoring glycaemic control

https://doi.org/10.1016/S0140-6736(96)90672-8Get rights and content

Abstract

Summary

Background To evaluate prospectively the clinical value of measuring serum concentrations of 1,5-anhydroglucitol (1,5AG) in monitoring glycaemia in patients with newly diagnosed non-insulin-dependent diabetes mellitus (NIDDM), we measured serum 1,5AG in 56 such patients.

Methods 28 patients (group A) were started on, and continuously received, an oral hypoglycaemic agent for at least 6 weeks. The other 28 patients (group B) were given such agents for 4 weeks, and then stopped taking them for at least 2 weeks. All patients were then followed for an additional 10 weeks. Serum 1,5AG, fructosamine, glycated haemoglobin (HbA1c), and self-monitoring of blood glucose were monitored every 14 days for 16 weeks.

Findings When sudden worsening of glycaemia occurred within 2 weeks, entailing withdrawal of oral treatment, 1,5AG accurately detected the slight change in glycaemia whereas HbA1c and fructosamine both failed to detect it. Although the change was detected by measurement of fasting plasma glucose (FPG) concentrations, FPG was less sensitive than 1,5AG. In patients with "near-normoglycaemia" (HbA1c about 6.5%) in the preceding 8 weeks, those who showed a lower concentration of 1,5AG (<10·0 μg/mL) manifested a higher mean daily plasma glucose concentration even though HbA1c measurement suggested good control of glycaemia. Results of 1,5AG were correlated more strongly with the FPG (r=0·790) and mean daily plasma glucose (r=-0·835) estimated on the same day than those estimated in the preceding 2, 4 and 8 weeks, and with a fall in the Spearman correlation coefficient at any preceding time interval.

Interpretation Because 1,5AG accurately detected a slight change in glycaemia without delay, it is suitable for use in monitoring for strict control of glycaemia, an important clinical goal.

References (28)

  • T. Yamanouchi et al.

    Transport and accumulation of 1,5-anhydro-D-glucitol in the human erythroleukemia cell line K-562

    J Biol Chem

    (1994)
  • T. Yamanouchi et al.

    Estimation of plasma glucose fluctuation with combination test of HbA1c and 1,5-anhydroglucitol

    Metabolism

    (1992)
  • The Diabetes Control and Complications Trial Research Group

    The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus

    N Engl J Med

    (1993)
  • Rj Koenig et al.

    Correlation of glucose regulation and hemoglobin A1c in diabetes mellitus

    N Engl J Med

    (1976)
  • Fj Service et al.

    Measurements of glucose control

    Diabetes Care

    (1987)
  • Js Yudkin et al.

    Unexplained variability of glycated haemoglobin in non-diabetic subjects not related to glycemia

    Diabetologia

    (1990)
  • Dm Nathan

    Hemoglobin A1c—infatuation or the real thing?

    N Engl J Med

    (1990)
  • T. Yamanouchi et al.

    Reduction and recovery of plasma 1,5-anhydro-D-glucitol level in diabetes mellitus

    Diabetes

    (1987)
  • T. Yamanouchi et al.

    Plasma 1,5-anhydro-D-glucitol as new clinical marker of glycemic control in NIDDM patients

    Diabetes

    (1989)
  • T. Yamanouchi et al.

    Mechanism for acute reduction of 1,5-anhydro-D-glucitol in rats treated with diabetogenic agents

    Am J Physiol

    (1990)
  • S. Kametani et al.

    Reduced renal reabsorption of 1,5-anhydroglucitol in diabetic rats and mice

    J Biochem

    (1987)
  • T. Yamanouchi et al.

    Reduction of plasma 1,5-anhydroglucitol (1-deoxyglucose) concentration in diabetic patients

    Diabetologia

    (1988)
  • Y. Akanuma et al.

    Urinary excretion of 1,5-anhydroglucitol accompanying glucose excretion in diabetic patients

    Diabetologia

    (1988)
  • Cited by (0)