Article Text
Research Article
A method for the quantification of human gastric G cell density in endoscopic biopsy specimens.
Abstract
A previously described method for estimating G cell density in endoscopic biopsy specimens has been modified to take into account observations of the way in which specimens behave when they are deformed and some of the length-measuring characteristics of a grid used to measure the length of tissue profiles. The relationships between particle densities in sections and particle densities in tissue of which the sections are representative are discussed.