Article Text

Download PDFPDF
Evaluation of a direct immunofluorescence test for diagnosing gonorrhoea.
  1. C A Ison,
  2. K McLean,
  3. J Gedney,
  4. P E Munday,
  5. D Coghill,
  6. R Smith,
  7. J R Harris,
  8. C S Easmon

    Abstract

    A new direct immunofluorescence reagent (Syva and Genetic Systems Inc) was evaluated for its ability to detect Neisseria gonorrhoeae in specimens from populations with a high prevalence of the infection. Gonorrhoea was diagnosed by culture in 45 of 105 (43%) urethral specimens from men and 17 of 90 (28%) urethral and 25 of 60 (42%) cervical specimens from women. In men the immunofluorescence test had a sensitivity of 84.4% and a specificity of 100%; Gram staining gave values of 94% and 100%, respectively. The sensitivity of the immunofluorescence test could be increased to 89% by testing duplicate smears. In women the immunofluorescence test had a sensitivity of 65% and a specificity of 98% for urethral samples and values of 72% and 94%, respectively for cervical samples. At both sites the sensitivity of the Gram stain was 40% and the specificity 100%. The testing of duplicate immunofluorescence smears increased the sensitivity to 76% for urethral and 88% for cervical samples.

    Statistics from Altmetric.com

    Request Permissions

    If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.