Article Text

Download PDFPDF
Accuracy of routine laboratory diagnosis of malaria in the United Kingdom.
  1. L M Milne,
  2. M S Kyi,
  3. P L Chiodini,
  4. D C Warhurst
  1. Department of Clinical Parasitology, Hospital for Tropical Diseases, London.

    Abstract

    AIMS--To study the accuracy of routine laboratory diagnosis of malaria with the aim of improving accuracy in diagnosis in the future. METHODS--A comparative study was made of all blood films submitted to two laboratories in London providing a slide-diagnostic service for malaria. RESULTS--There were 17 Plasmodium ovale infections, and of these only five (29.4%) were correctly diagnosed by the submitting laboratory; whereas of 210 other single species infections, 162 (77.1%) were correctly diagnosed (chi 2 = 18.4, p < 0.0001). There were six patients with mixed infections; only one (16.7%) was correctly diagnosed, whereas of 227 single species infections, 167 (73.6%) were correctly diagnosed (p = 0.007, using Fisher's exact test). There was no significant association between the presence of technical faults or numerous platelets and incorrect diagnosis. CONCLUSIONS--Plasmodium ovale and mixed infections were diagnosed incorrectly significantly more often than other species. The presence of technical faults or numerous platelets had no significant effect on whether or not submitting laboratories correctly diagnosed malaria.

    Statistics from Altmetric.com

    Request Permissions

    If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.