Accuracy of serology for the diagnosis of Helicobacter pylori infection--a comparison of eight kits.
  1. M H Wilcox,
  2. T H Dent,
  3. J O Hunter,
  4. J J Gray,
  5. D F Brown,
  6. D G Wight,
  7. E P Wraight
  1. Clinical Microbiology and Public Health Laboratory, Addenbrooke's Hospital, Cambridge.

    Abstract

    AIMS: To determine the accuracy of eight commercially available kits for the serological diagnosis of Helicobacter pylori infection, and hence whether a serology service could be introduced to reduce endoscopy workload. METHODS: Eighty four patients newly presenting to their general practitioners with dyspepsia were recruited. Gold standard diagnosis of H pylori infection was obtained both by a histological examination of gastroduodenal biopsy specimens and by the 14C-urea breath test (UBT). The performance of six quantitative and two qualitative enzyme linked immunosorbent assays for H pylori IgG, used according to the manufacturers' instructions, with serum samples obtained during the endoscopy visit, were compared. RESULTS: The study population had a median age of 45 years, and the prevalence of H pylori infection was 35%. With one exception, where the patient had received a course of anti-H pylori treatment between endoscopy and UBT, there was 100% concordance in the results of the two gold standard techniques. Discordant serology results were more common in patients aged > 50 years (42% of the total) than in younger patients (21%), and this was most noticeable in uninfected patients. The sensitivity of the kits was good (90-100%), but specificity was more variable (76-96%), and the rate of equivocal results was unacceptably high in some cases (0-12%). The overall accuracy of the kits ranged from 83 to 98%. Two kits in particular performed well (Pylori-Elisa II, Bio-Whitaker and Premier, Launch; qualitative) with 98% and 100% accuracy, respectively. CONCLUSIONS: In a symptomatic population with a prevalence of H pylori infection of 35%, particularly in patients aged < 50 years, some but not all serology kits may be used as a highly accurate and inexpensive alternative to the gold standard techniques.

    Statistics from Altmetric.com

    Request Permissions

    If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.