Abstract

Aim: The University Hospitals of Leicester NHS Trust microbiology laboratory receives 150 000 urine samples each year, approximately 80% of which prove to be culture negative. The aim of this study was to reduce the proportion of culture negative urines arriving in the laboratory, by producing local evidence based guidelines for the use of urine dipstick testing at point of care within the trust’s three acute hospitals.

Methods: One thousand and seventy six unborated urine samples were dipstick tested at the point of care using an automatic strip reader. Quantitative results for the four infection associated markers—leucocyte esterase, nitrite, blood, and protein—were compared with the results of conventional laboratory microscopy and culture.

Results: The performance of different marker combinations was calculated against the routine laboratory methods. One hundred and seventy five (16.3%) samples were negative for all four markers. Of these dipstick negative samples, only three (1.7% of all true positives) were positive by culture. The absence of all four infection associated markers was found to have a greater than 98% negative predictive value and a sensitivity and specificity of 98.3% and 19.2%, respectively.

Conclusions: A urinary dipstick testing algorithm for infection associated markers was derived for use in hospital patients to screen out negative urines. Two years after distributing the algorithm and promoting access to reagent strips and strip readers, a reduction in the urine workload has been seen against an otherwise increasing laboratory specimen load.

  • CFU, colony forming units
  • GGH, Glenfield General Hospital
  • LGH, Leicester General Hospital
  • LRI, Leicester Royal Infirmary
  • and NPUDT, near patient urine dipstick testing
  • NPV, negative predictive value
  • UTI, urinary tract infection
  • algorithm
  • infection associated markers
  • urinary tract infection
  • urine dipstick testing
  • workload

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.