Article Text
Abstract
Aim To investigate whether incorrect order of draw of blood samples during phlebotomy causes in vitro potassium ethylenediaminetetraacetic acid EDTA (kEDTA) contamination of blood samples.
Methods Serum kEDTA, potassium, calcium, magnesium, alkaline phosphatase, zinc and iron concentrations were measured in blood samples drawn before and after collecting blood into kEDTA containing sample tubes by an experienced phlebotomist using the Sarstedt Safety Monovette system.
Results EDTA was undetectable in all samples. The concentrations of other analytes were similar in blood samples drawn before and after collection of the EDTA blood sample.
Conclusion Order of draw of blood samples using the Sarstedt Safety Monovette system has no effect on serum biochemistry results, when samples are taken by an experienced phlebotomist.
- Order of draw
- EDTA contamination
- hyperkalaemia
- hypocalcaemia
- biochemistryelectrolytes
- metabolism
- laboratory tests
- laboratory management
- chemical pathology
- education
- endocrinology
- entero-insular axis
- cardiovascular
- hypoglycaemia
- thyroid endocrinology
Statistics from Altmetric.com
Footnotes
Competing interests None.
Ethics approval This study was conducted with the approval of the Coventry and Warwickshire Research Ethics Committee.
Provenance and peer review Not commissioned; externally peer reviewed.