RT Journal Article SR Electronic T1 A new disinfectant JF Journal of Clinical Pathology JO J Clin Pathol FD BMJ Publishing Group Ltd and Association of Clinical Pathologists SP 318 OP 320 DO 10.1136/jcp.19.4.318 VO 19 IS 4 A1 Philip W. Ross YR 1966 UL http://jcp.bmj.com/content/19/4/318.abstract AB Qualitative and quantitative tests have been carried out to assess the value of Cidex1, a glutaraldehyde solution, as a disinfectant. Most of the tests were qualitative and were carried out in conditions as closely resembling those found in hospital practice as possible. Recently used anaesthetic equipment, catheters, and a cystoscope, which had been artificially contaminated with suspensions of Staph. aureus, Ps. pyocyanea, and Esch. coli, were used in the tests. The results show Cidex to be a useful disinfectant with a valuable potential in disinfecting hospital articles which, due to their perishable nature or the fragility of component parts, cannot be treated by physical means.