PT - JOURNAL ARTICLE AU - Hoctor, D AU - Bottomley, J AU - Hyde, K AU - Gowenlock, A H AU - Maciver, J E TI - Comparison of liquid and dried sodium citrate as the anticoagulant for Thrombotest and prothrombin time estimations. AID - 10.1136/jcp.34.8.902 DP - 1981 Aug 01 TA - Journal of Clinical Pathology PG - 902--905 VI - 34 IP - 8 4099 - http://jcp.bmj.com/content/34/8/902.short 4100 - http://jcp.bmj.com/content/34/8/902.full SO - J Clin Pathol1981 Aug 01; 34 AB - Samples which are taken for the Quick one-stage prothrombin time estimation for the control of patients receiving oral anticoagulant treatment are by convention taken into liquid sodium citrate anticoagulant. Dried sodium citrate has been rejected on the grounds that excessive haemolysis causes activation of clotting factors and therefore falsely short clotting times. Tests were performed with both liquid and dried sodium citrate as an anticoagulant for prothrombin time and Thrombotest. No clinically significant difference between the values given by the two anticoagulants was observed.