TY - JOUR T1 - Validity of whole slide images for scoring HER2 chromogenic in situ hybridisation in breast cancer JF - Journal of Clinical Pathology JO - J Clin Pathol SP - 992 LP - 997 DO - 10.1136/jclinpath-2016-203644 VL - 69 IS - 11 AU - Shaimaa Al-Janabi AU - Anja Horstman AU - Henk-Jan van Slooten AU - Chantal Kuijpers AU - Clifton Lai-A-Fat AU - Paul J van Diest AU - Mehdi Jiwa Y1 - 2016/11/01 UR - http://jcp.bmj.com/content/69/11/992.abstract N2 - Aim Whole slide images (WSIs) have stimulated a paradigm shift from conventional to digital pathology in several applications within pathology. Due to the fact that WSIs have not yet been approved for primary diagnostics, validating their use for different diagnostic purposes is still mandatory. The aim of this study was to test the validity of WSI in assessing human epidermal growth factor receptor 2 (HER2) status in breast cancer specimens using chromogenic in situ hybridisation (CISH).Materials and methods Ninety-six HER2 CISH slides were scored by two observers on a light microscope (400× viewing magnification) and on WSI (40× scanning magnification, one focus plane) with a minimum of 6 weeks washout period. The concordance between digital and microscopic HER2 scores was assessed.Results Digitally, 93/96 cases could be assessed (96.8%). Microscopic and digital evaluation of HER2 amplification status were concordant in 68/93 cases ((73.1%, 95% CI: 0.639 −0.823), κ 0.588). CISH underscoring was most noticeable in the amplified and equivocal categories while the highest level concordance was seen in cases with a normal copy number. Additionally there was a noticeable tendency to underestimate the average HER2 scores on WSI: lower in 59 and higher in 11 cases. There was no major difference in time spent for microscopic scoring (86.9 s) and digital scoring (81.7 s).Conclusions There was a reasonable concordance between microscopic scoring and WSI-based scoring of HER2 copy number of CISH slides. Nevertheless, WSIs scanned on a single focal plane are insufficient to assess HER2 gene amplification status by scoring CISH due to the noticeable tendency towards digitally underestimating the number of HER2 spots. Scanning at multiple focus planes may offer better resolution for improved digital CISH spot counting. ER -