Volume 13, Issue 6, December 1980, Pages 259-261
Clinical Biochemistry

A computer directed pneumatic tube system: its effects on specimens

https://doi.org/10.1016/S0009-9120(80)80005-1Get rights and content

When the new Erie County Medical Center (Buffalo, NY) was built, a pneumatic tube network, manufactured by Mosler Airmatic and Electronic Systems Company, was installed. This network, called the Mosler System 4000, was designed to handle 600 transactions per hour in the hospital, and therefore had to have a high carrier speed (8m/sec). When blood specimens were sent through the system, blood cells were slightly damaged and lactic dehydrogenase activity in the serum was consistently elevated. But neither acidic phosphatase, potassium, blood gases nor urinary casts were significantly affected by tube transport.

References (9)

  • McClellanE.K. et al.

    Effect of pneumatic tube transport system on the validity of determinations in blood chemistry

    Am. J. Clin. Pathol.

    (1964)
  • DelbruckA. et al.

    Uber den Einfluss des Rohrpost transportes auf klinischen Untersuchungsmaterial unter verschiedenen Betriebsbedingungen

    Klin. Chem. Klin. Boochem.

    (1968)
  • SteigeH. et al.

    Evaluation of pneumatic tube system for delivery of blood specimens

    Clin. Chem.

    (1971)
  • PragayD.A. et al.

    Evaluation of an improved pneumatic tube system suitable for transportation of blood specimens

    Clin. Chem.

    (1974)
There are more references available in the full text version of this article.

Cited by (25)

  • Pre-analytical effects of pneumatic tube system transport on routine haematology and coagulation tests, global coagulation assays and platelet function assays

    2017, Thrombosis Research
    Citation Excerpt :

    This is why the results of this study cannot be extended, without great caution, to all centres using PTS having different characteristics. The speed of our PTS is 5.2 m/s, which belongs to the high average speed of PTS transport described in literature, with a range from 3 m/s to 8 m/s [2,4,9,11,19,23,33], but systems with lower speeds might have different results than those presented in this study. In conclusion, despite the promising results obtained with the longest PTS yet to be tested, each laboratory should evaluate their own PTS before using it in daily practice, especially for the transport of platelet samples and before global haemostasis assays.

  • Hemolysis in diagnostic samples

    2009, Revista del Laboratorio Clinico
  • A novel comparative model proposal for hospital pneumatic systems

    2022, Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
View all citing articles on Scopus
*

Post doctoral fellows at Clinical Chemistry Dept.

View full text