Diagnostic value of ultrasound-guided fine-needle aspiration biopsy, core-needle biopsy, and evaluation of combined use in the diagnosis of breast lesions

J Am Coll Surg. 2000 Mar;190(3):299-303. doi: 10.1016/s1072-7515(99)00300-2.

Abstract

Background: To investigate whether ultrasound-guided core-needle biopsy (US-CNB) has more diagnostic value for breast tumors than ultrasound-guided fine-needle aspiration biopsy (US-FNAB) and to evaluate their combined use in patients with breast tumors.

Study design: US-FNAB was carried out in 233 patients with breast tumors (254 lesions); both US-FNAB and US-CNB (combined biopsy) were performed in 81 of these patients (82 lesions). The diagnosis obtained by US-FNAB and US-CNB was compared with the surgical findings and the diagnostic value of US-CNB and combined biopsy were retrospectively evaluated.

Results: The sensitivity of US-FNAB was 86.9%, the specificity was 78.6%, and the accuracy was 84%. In contrast, the sensitivity of US-CNB was 86.2%, the specificity was 95.8%, and the accuracy was 89%. The specificity of US-CNB was significantly higher than that of US-FNAB and the inadequate biopsy rate of US-CNB was significantly lower than that of US-FNAB. For combined biopsy, the sensitivity, specificity, and accuracy were all 100%. The sensitivity, specificity, and accuracy of combined biopsy were significantly higher than those of US-FNAB.

Conclusions: These findings suggest that US-CNB is more useful than US-FNAB, and that a combination of US-CNB and US-FNAB can markedly improve the preoperative diagnosis of breast cancer.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Biopsy, Needle* / methods
  • Breast Neoplasms / pathology*
  • Female
  • Humans
  • Middle Aged
  • Predictive Value of Tests
  • Retrospective Studies
  • Sensitivity and Specificity
  • Ultrasonography